6 Avaya MultiVantage Software-Controlled Maintenance:
Table 67. TEST #140 Red Alarm Inquiry Test Continued
Error
Test
Code
Result
Any
NO
BOARD

Yellow Alarm Inquiry Test (#141)

Receiving a Yellow alarm from a remote DS1 endpoint indicates that the remote DS1 endpoint has an
out-of-frame condition. The Yellow Alarm Inquiry Test is used to determine whether the remote DS1
endpoint is transmitting a Yellow alarm. The DS1-MM Interface Media Module takes 500 msec to
recognize and report a Yellow alarm and 500 msec to recognize and report that a Yellow alarm
condition is cleared.
When the MM-DS1 Interface Media Module detects a Yellow alarm from the remote DS1 endpoint,
it sends a YELLOW-ALARM uplink message to the maintenance software. After the maintenance
software receives the YELLOW-ALARM message, the Yellow Alarm Inquiry Test is run to confirm
the Yellow alarm. Once the Yellow alarm is confirmed, the maintenance software places all trunks or
ports on the Media Module into the out-of-service state. The Inquiry Test runs every 10 minutes until
the Yellow alarm is cleared.
When the Yellow alarm is cleared, the maintenance software restores all trunks or ports on the DS1-
MM Interface Media Module back to their previous service state before the Yellow alarm was raised.
This Yellow alarm corresponds to the yellow F2 state documented in CCITT Recommendation I.431.

Remote Multiframe Alarm

Remote Multiframe Alarm (RMA) indicates that the remote DS1 endpoint is in a Loss of Multiframe
Alarm condition while the DS1-MM Interface Media Module is administered using the DMI-BOS
common channel signaling. The RMA is handled as a Yellow alarm.
222
Description/ Recommendation
The test could not relate the internal ID to the port (no board). This
could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, or an insane board is inserted.
Ensure that the board translations are correct. Execute the add ds1
GGGVS command to administer the DS1-MM interface if it is not
already administered.
If the board was already administered correctly, check the error log
to determine whether the board is hyperactive. If this is the case, the
board is shut down. Reseating the board will re-initialize the board.
If the board was found to be correctly inserted in step 1, then issue
the busyout board command.
Issue the reset board command.
Issue the release busy board command.
Issue the test board long command.
This should re-establish the linkage between the internal ID and the
port.