Maintenance-Object Repair Procedures
m. Error Type 2561–2668 — System software received an indication that the
socket was closed due to an error. Errors are reported as log only. Errors
logged here are for the sockets that had no processor channels associated
with them, for example, sockets to read SNMP data. The counter base is
offset by the application type of the application associated with this socket
that is down. The Aux Data field of the log entry contains this application's
number, for example, a SNMP application would have its application
number in the Aux Data field.
n. Error Type 2817–2819 — Congestion Query test (#600) failed.
The Error Types correspond to the descriptions:
2817
2819
If:
Active buffers exceed threshold,
1. See
o. Error Type 3073 — Remote Socket Control Link (RSCL) or Link Status
test (#601) failed. This failure can be due to:
If:
RSCL disconnects at link level
Link cannot be reconnected quickly
p. Error Type 3330 — Critical failure in Packet bus interface.
Below, Error Types correspond to descriptions.
If the switch detects:
1 error,
2 errors in 15 minutes,
1. Attempt to clear the alarm (reset board UUCSS).
2. If alarm persists, replace circuit pack.
8-1822
Issue 1 May 2002
NOTE:
2561–2668 is a range of reserved numbers for future applications.
2570 currently represents an SNMP socket failure.
Every buffer exhausted.
Utilized buffers exceed threshold.
''Congestion Query Test (#600)'' on page 8-1830
Fail 3601s.
This circuit pack
The packet bus
The packet interface circuit pack.
Then it:
Resets circuit pack.
Raises MINOR alarm.
Then:
VAL enters congested state.
Then:
Link fails
Switch raises MINOR alarm
for Abort and
555-233-143