Download Print this page

Power-Inline Description - Allied Telesis IE340 Series Command Reference Manual

Industrial ethernet layer 3 switches
Hide thumbs Also See for IE340 Series:

Advertisement

P
E
C
OWER OVER
THERNET
OMMANDS
-
POWER
INLINE DESCRIPTION

power-inline description

Overview
This command adds a description for a Powered Device (PD) connected to a PoE
port.
The no variant of this command clears a previously entered description for a
connected PD, resetting the PD description to the default (null).
Syntax
power-inline description <pd-description>
no power-inline description
Default
No description for a connected PD is set by default.
Mode
Interface Configuration
Usage notes
Select a PoE port, a list of PoE ports, or a range of PoE ports with the preceding
interface (to configure)
all be PoE capable ports.
Examples
To add the description "Desk Phone" for a connected PD on port1.0.5, use the
following commands:
awplus#
awplus(config)#
awplus(config-if)#
To clear the description for the connected PD on port1.0.5, use the following
commands:
awplus#
awplus(config)#
awplus(config-if)#
Related
show power-inline interface
commands
show running-config
Command
Version 5.4.8-0.2: added to x550 series products
changes
C613-50631-01 Rev A
Parameter
<pd-description>
configure terminal
interface port1.0.5
configure terminal
interface port1.0.5
<power-inline>
Command Reference for IE340 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
Description
Description of the PD connected to the PoE capable port
(with a maximum 256 character string limit per PD
description).
command. If you specify a range or list of ports they must
power-inline description Desk Phone
no power-inline description
815