Program
Program Name
Number
80-04-03
Call Progress Tone Detector
Setup – S/N Ratio
80-04-04
Call Progress Tone Detector
Setup – No Tone Time
80-04-05
Call Progress Tone Detector
Setup – Pulse Count
80-04-06
Call Progress Tone Detector
Setup – ON minimum time
80-04-07
Call Progress Tone Detector
Setup – ON maximum time
80-04-08
Call Progress Tone Detector
Setup – OFF minimum time
2 - 760
Description/Comments
Use to define the S/N ratio for the
Call Progress Tone Detector.
Use to define the no tone time for
the Call Progress Tone Detector.
Use to define the pulse count for
the Call Progress Tone Detector.
Use to define the on minimum time
for the Call Progress Tone
Detector.
Use to define the on maximum
time for the Call Progress Tone
Detector.
Use to define the off minimum time
for the Call Progress Tone
Detector.
UNIVERGE SV8100
Assigned Data
0~4 (0dB ~ -20dB)
default:
Type 1 (DT) – 4
(-20dB)
Type 2 (BT) – 4
(-20dB)
Type 3 (RBT) – 4
(-20dB)
Type 4, Type 5 – 0
0~255 (30+30-7680ms)
default:
Type 1 (DT) – 132
(3990ms)
Type 2 (BT) – 132
(3990ms)
Type 3 (RBT) – 132
(3990ms)
Type 4, Type 5 – 0
1~255
default:
Type 1 (DT) – 1
Type 2 (BT) – 1
Type 3 (RBT) – 1
Type 4, Type 5 – 0
1~255 (30+30-7680ms)
default:
Type 1 (DT) – 9 (300ms)
Type 2 (BT) – 9 (300ms)
Type 3 (RBT) – 25
(780ms)
Type 4, Type 5 – 0
0~255 (30+30-7680ms)
default:
Type 1 (DT) – 0
Type 2 (BT) – 14
(450ms) [ET]
Type 3 (RBT) – 40
1230ms)
Type 4, Type 5 – 0
1~255 (30+30-7680ms)
default:
Type 1 (DT) – 1 (60ms)
Type 2 (BT) – 9 (300ms)
Type 3 (RBT) – 83
(2520ms)
Type 4, Type 5 – 0
Multiple Trunk Types
Level
1
2
3