Program
Program Name
Number
80-03-06
DTMF Tone Receiver Setup –
Backward twist level
80-03-07
DTMF Tone Receiver Setup – ON
detect time
80-03-08
DTMF Tone Receiver Setup – OFF
detect time
80-04-01
Call Progress Tone Detector
Setup – Detection Level
80-04-02
Call Progress Tone Detector
Setup – Min. Detection Level
2 - 1172
Description/Comments
Use this option to define the
backwards twist level for DTMF
Tone Receiver.
Use this option to define the On
dectection time for DTMF Tone
Receiver.
Use this option to define the Off
dectection time for DTMF Tone
Receiver.
Define the various levels and timers
for the Call Progress Tone
Detector.
Use this option to set the Detection
Level.
Define the various levels and timers
for the Call Progress Tone
Detector.
Use this option to set the minimum
detection level.
UNIVERGE SV8100
Assigned Data
0~9
(1dB ~ 10dB)
default:
All Receivers = 9
1~255
(15+ 15 ms ~ 3825 ms)
default:
All Receivers = 1
1~255
(15+ 15 ms ~ 3825 ms)
default:
All Receivers = 1
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
default:
Type 1 (DT) – 0
(-25dBm)
Type 2 (BT) – 0
(-25dBm)
Type 3 (RBT) – 0
(-25dBm)
Type 4, Type 5 – 0
0~15
detect level 0:
–15dBm(0) to
–30dBm(15)
detect level 1:
–30dBm(0) to
–45dBm(15)
detect level 2:
–40dBm(0) to
–55dBm(15)
default:
Type 1 (DT) – 15
(-25dBm)
Type 2 (BT) – 15
(-25dBm)
Type 3 (RBT) – 15
(-25dBm)
Type 4, Type 5 – 0