ISDN – PRI Installation
Program
Program Name
Number
10-03-04
ETU Setup (PRTA PKG Setup) –
Layer 3 Timer Type
10-03-06
ETU Setup (PRTA PKG Setup) –
Length of Cable
10-03-08
ETU Setup (PRTA PKG Setup) –
Dial Sending Mode
10-03-09
ETU Setup (PRTA PKG Setup) –
Dial Information Element
10-03-18
ETU Setup (PRTA PKG Setup) –
Type of Number
10-03-19
ETU Setup (PRTA PKG Setup) –
Numbering Plan Identification
2 - 662
Description/Comments
Setup and confirm the Basic
Configuration data for each
CD-PRTA This program selects
the Layer 3 timer type (1~5). Each
timer value of Layer 3 is set up for
each type in Program 81-06
(T-Bus).
Setup and confirm the Basic
Configuration data for each
CD-PRTA. Select the length of
cable to be used.
ISDN protocol definition. Select
either enblock or overlap sending.
ISDN protocol definition. If Overlap
Sending is selected in Program
10-03-08, select either Keypad
Facility (0) or Called Party Number
(1) for the dial information
element.
Select the number type for the
ISDN circuit.
Select the Numbering Plan used
for the ISDN circuit.
UNIVERGE SV8100
Assigned Data
1~5
(default = 1)
0 = Level 1
1 = Level 2
2 = Level 3
3 = Level 4
4 = Level 5
(default = 2)
0 = Enblock Sending
1 = Overlap Sending
(default = 0)
0 = Keypad Facility
1 = Called Party Number
(default = 0)
0 = Unknown
1 = International number
2 = National number
3 = Network Specific
number
4 = Subscriber number
5 = Abbreviated number
(default = 2)
0 = Unknown
1 = ISDN numbering
plan
2 = Data numbering plan
3 = Telex numbering
plan
4 = National standard
numbering plan
5 = Private numbering
plan
(default = 1)
ISDN Compatibility
Level
1
2
3

Hide quick links: