UNIVERGE SV8100
Program
Program Name
Number
80-03-06
DTMF Tone Receiver Setup –
Backwards Twist Level
80-03-07
DTMF Tone Receiver Setup – ON
Detect Time
80-03-08
DTMF Tone Receiver Setup –
OFF Detect Time
80-04-01
Call Progress Tone Detector
Setup – Detection Level
80-04-02
Call Progress Tone Detector
Setup – Min. Detection Level
SV8100 Features and Specifications Manual
Description/Comments
Use this option to define the
backwards twist level for DTMF
Tone Receiver.
Use this option to define the On
detection time for DTMF Tone
Receiver.
Use this option to define the Off
detection time for DTMF Tone
Receiver.
Use to define the detection levels
for the Call Progress Tone
Detector.
Use to define the minimum
detection levels for the Call
Progress Tone Detector.
Assigned Data
0~9
(1dB ~ 10dB)
default:
All Receivers =
1~255
(15+ 15 ms ~ 3825 ms)
default:
All Receivers = 1
1~255
(15+ 15 ms ~ 3825 ms)
default:
All Receivers = 1
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
default:
Type 1 (DT) – 0
(-25dBm)
Type 2 (BT) – 0
(-25dBm)
Type 3 (RBT) – 0
(-25dBm)
Type 4, Type 5 – 0
0~15
detect level 0:
–15dBm(0) to
–30dBm(15)
detect level 1:
–30dBm(0) to
–45dBm(15)
detect level 2:
–40dBm(0) to
–55dBm(15)
default:
Type 1 (DT) – 15
(-25dBm)
Type 2 (BT) – 15
(-25dBm)
Type 3 (RBT) – 15
(-25dBm)
Type 4, Type 5 – 0
Issue 1.0
Level
1
2
3