NEC Univerge SV8100 Features And Specifications Manual page 465

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Program Name
Number
10-03-01
ETU Setup (DLC PKG Setup) –
(1)
Terminal Type (B1)
10-03-06
ETU Setup (DLC PKG Setup) –
Terminal Type (B2)
10-05-01
General Purpose Relay Setup –
Slot No. Physical Port of DLC
Sensor Circuit No.
11-12-36
Service Code Access (for
Service Access) – Door Box
Access
15-07-01
Programmable Function Keys
32-01-01
Door Box Timers – Door Box
Answer Time
32-01-02
Door Box Timers – Door Lock
Cancel Time
SV8100 Features and Specifications Manual
Description/Comments
Use to setup and confirm the Basic
Configuration data for terminal type
(B1).
Use to setup and confirm the Basic
Configuration data for terminal type.
For DLC package support, set the
terminal type to 8 [PGD (for Door
Box)]. First set 10-03-01 to 0 with
no device plugged into that port,
then plug the device in and the
system should recognize it as a
door box and then set Program
10-03-06.
Define which Relay circuits (5~8) on
a PGD(2)-U( ) ADP Adapter are
used for General Purpose Relay.
If the service code for Doorphone
Access is not acceptable, change it
here.
Assign a function key for External
Call Forward by Doorphone (Code
54).
Set the time a user has to answer
the Door Box chimes.
Set the time the Door Box strike
stays open when the single line
telephone user hookflashes or a
multiline terminal user presses
Recall.
Assigned Data
1
0 = Not set
1 = Multiline Terminal
2 = SLT Adapter
3 = Bluetooth Cordless
Handset
6 = PGD (Paging)
7 = PGD (Tone Ringer)
8 = PGD (Doorbox)
9 = PGD (ACI)
10 = DSS Console
11 = -- Not Used --
(default = 0))
0 = Not set
6 = PGD(2)-U( ) ADP
(Paging)
7 = PGD(2)-U( ) ADP
(Tone Ringer)
8 = PGD(2)-U( ) ADP
(Door Box)
9 = PGD(2)-U( ) ADP
(ACI)
12 = APR (B2 Mode)
(default = 0)
Slot No: 0~24
DCLA Port: 0~16
Relay No: 0, 5~8
After each entry,
pressing the
Transfer Key
advances to the
next entry.
(default = 0 - 0 - 0)
MLT, SLT
(default = 702)
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~ 99
(Appearance Function
Code) (Service Code
752 by default)
0~64800 (seconds)
(default = 30 seconds)
0~64800 (seconds)
(default = 10 seconds)
Issue 1.0
Level
2
3
2 - 441