UNIVERGE SV8100
Program
Program Name
Number
51-07-02
Net-Link Primary Compulsion
Specification Setting – Package
Reset Timing Option
51-08-01
Primary Net-Link Setting – IP
Address of New Primary System
51-08-02
Primary Net-Link Setting –
System ID of New Primary System
51-09-01
Net-Link Communication Port
Settings – Primary Waiting Port
51-09-02
Net-Link Communication Port
Settings – Communication
Waiting Port
51-09-03
Net-Link Communication Port
Settings – Secondary
Communication Port
51-09-04
Net-Link Communication Port
Settings – Primary Search Port
51-09-05
Net-Link Communication Port
Settings – Primary Detection Port
51-09-06
Net-Link Communication Port
Settings – Database Replication
Communication Listening Port
51-09-07
Net-Link Communication Port
Settings – Database Replication
Primary Detection Port
51-10-01
Virtual Slot Setting – Number of
Available Virtual Slots
SV8100 Features and Specifications Manual
Description/Comments
When Forced Change Primary
System is done, all packages will
reset. This option can select the
timing of package reset.
0 = Reset when all packages are in
idle condition, otherwise reject
Primary System Integration.
1 = Anytime
Enter target IP address for New
Primary system. When the Forced
Change Primary system is done, this
setting will be erased.
When set to 0, top priority Primary
system is assumed to be the new
Primary system.
Sets the communication port that the
Primary system uses to
communicate with the Secondary
system.
Port used to communicate between
nodes. It is always opened by all
nodes.
Secondary system communicates
with Primary system at this port
number. If 0 is specified, temporary
port is selected by dynamic.
When Fail-Over occurred, each
system communicates with other
system at this port number.
If 0 is set, temporary port is selected
by dynamic.
If 0 is not specified, the number and
continuous maximum 50 number is
used.
(Ex. 5000 is specified 5001,
5002...5049 will be used).
Enter port number to seek the Top
Priority Primary system.
If 0 is specified, temporary port is
selected by dynamic.
This port is used to replicate
database.
This port is used to replicate
database.
If 0 is specified, temporary port is
selected by dynamic.
240 slots can be controlled in
NetLink. This command can check
how many slots are available.
Assigned Data
0 = Off
1 = On
(default = 0)
0.0.0.0 ~
126.255.255.254
128.0.0.1 ~
191.255.255.254
192.0.0.1 ~
223.255.255.254
(default = 0.0.0.0)
0~50
(default not assigned)
0~65535
(default = 58000)
0~65535
(default = 58001)
0~65535
(default = 0)
0~65535
(default = 0)
0~65535
(default = 0)
0~65535
58002)
(default =
0~65535
(default = 0)
(default not assigned)
Issue 1.0
Level
1
2
3
2 - 1035