NEC Univerge SV8100 Features And Specifications Manual page 1100

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 1.0
Program
Program Name
Number
34-09-04
ANI/DNIS Service Options –
Route Table Setup of Target Dial
34-09-05
ANI/DNIS Service Options – ANI/
DNIS Display as Target Dial Name
2 - 1076
Description/Comments
The option sets how the system
uses the route data (gathered in
Item 3) to route incoming ANI/DNIS
calls (0 = ABB Table [Program 13-
04], 1 = DID Table [Program 22-
11]).
If option 2 is selected and the call
is to be routed using the DID table
(1), up to eight digits can be
matched. The number of expected
digits set in Program 22-09-01
must match the ANI digits defined
in Program 22-11-01. For example,
if an ANI/DNIS number received
was 2035551234 3001 and
Program 22-09-01=4, then the
entry in Program 22-11-01 must be
1234 with the defined target
extension.
If the call is to be routed using the
ABB table (0), up to 24 digits can
be matched. Define the range of
the ABB table to be used in
Program 34-09-06. The data is
then compared to the entries in
Program 13-04-01 and then routed
according to Program 13-04-03.
Use this option to set if ANI data
should appear on telephone
displays as part of Caller ID
display.
T1 Trunking (with ANI/DNIS Compatibility)
UNIVERGE SV8100
Assigned Data
0 = SPD Table (Program
13-03)
1 = DID Table (Program
22-11)
(default = 0 for
COS 1~15)
Caller ID Display:
0 = Display Off
1 = Display On
(default = 1 for
COS 1~14
default = 0 for COS 15)
Level
1
2
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents