NEC Univerge SV8100 Features And Specifications Manual page 614

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 1.0
Program
Program Name
Number
11-14-15
Service Code Setup (for Hotel) –
Room Status Change for Other
Extension
11-14-16
Service Code Setup (for Hotel) –
Room Status Output
11-14-17
Service Code Setup (for Hotel) –
Hotel Room Monitor
11-14-18
Service Code Setup (for Hotel) –
Set Hotel PMS Code Restriction
15-03-01
Single Line Telephone Basic
Data Setup – SLT Signaling Type
15-03-04
Single Line Telephone Basic
Data Setup – Flashing
20-06-01
Class of Service for Extensions
20-13-11
Class of Service Options
(Supplementary Service) – Room
Monitor, Initiating Extension
20-13-13
Class of Service Options
(Supplementary Service) –
Continued Dialing (DTMF) Signal
on ICM Call
20-13-16
Class of Service Options
(Supplementary Service) –
Barge-In, Receive
2 - 590
Description/Comments
Use to customize the room status
change for other extension Service
Codes which are used with the
Hotel/Motel feature (requires
CD-CP00-AU to be licensed for
Hotel/Motel).
Use to customize the room status
output Service Codes which are
used with the Hotel/Motel feature
(requires CD-CP00-AU to be
licensed for Hotel/Motel).
Use to customize the hotel room
monitor Service Codes which are
used with the Hotel/Motel feature
(requires CD-CP00-AU to be
licensed for Hotel/Motel).
Use to customize the set hotel PMS
code restriction Service Codes
which are used with the Hotel/Motel
feature (requires CD-CP00-AU to
be licensed for Hotel/Motel).
Use this option to tell the system
the type of dialing the connected
telephone uses.
Enables/disables Flash for single
line (500/2500 type) telephones.
Assign a Class of Service (1~15) to
extensions.
Turns Off (0) or On (1) an extension
user ability to Room Monitor other
extensions.
Turns Off (0) or On (1) the
extension ability to use Continued
Dialing, which allows DTMF signal
sending while talking on extension.
In an extension Class of Service,
turns On (1) or Off (0) Barge-In at
the receiving extension (i.e., Barge-
In receive).
UNIVERGE SV8100
Assigned Data
1
MLT, SLT
(default = 641)
MLT
(default = 642)
MLT, SLT
(default = 675)
MLT
(default = 666)
0 = DP
1 = DTMF
(default = 1)
0 = No
1 = Yes
(default = 1)
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension
ports = Class 1
0 = Off
1 = On
(default = 0 for
COS 1~15)
0 = Off
1 = On
(default = 1 for
COS 1~15)
0 = Off
1 = On
(default = 0 for
COS 1~15)
Hotel/Motel
Level
2
3