NEC Univerge SV8100 Features And Specifications Manual page 675

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program
Program Name
Number
84-01-12
H.323 Trunk Basic Information
Setup – G.723 VAD mode
84-01-15
H.323 Trunk Basic Information
Setup – Jitter Buffer Mode
84-01-16
H.323 Trunk Basic Information
Setup – G.711 Jitter Buffer (min)
84-01-17
H.323 Trunk Basic Information
Setup – G.711 Jitter Buffer
(average)
84-01-18
H.323 Trunk Basic Information
Setup – G.711 Jitter Buffer (max)
84-01-19
H.323 Trunk Basic Information
Setup – G.723 Jitter Buffer (min)
84-01-20
H.323 Trunk Basic Information
Setup – G.723 Jitter Buffer
(average)
84-01-21
H.323 Trunk Basic Information
Setup – G.723 Jitter Buffer (max)
84-01-22
H.323 Trunk Basic Information
Setup – VAD Threshold
84-01-23
H.323 Trunk Basic Information
Setup – Idle Noise Level
84-01-24
H.323 Trunk Basic Information
Setup – Echo Canceller Mode
84-01-25
H.323 Trunk Basic Information
Setup – Echo Canceller Tail Size
84-01-26
H.323 Trunk Basic Information
Setup – Echo Canceller NLP
Mode
SV8100 Features and Specifications Manual
Description/Comments
Use to define the G.723 VAD mode
for H.323.
Use to define the jitter buffer mode
for H.323.
Use to define the G.711 jitter buffer
(minimum) for H.323.
Use to define the G.711 jitter buffer
(average) for H.323.
Use to define the G.711 jitter buffer
(maximum) for H.323.
Use to define the G.723 jitter buffer
(minimum) for H.323.
Use to define the G.723 jitter buffer
(average) for H.323.
Use to define the G.723 jitter buffer
(maximum) for H.323.
Use to define the VAD threshold for
H.323.
Use to define the idle noise level for
H.323.
Use to define the echo canceller
mode for H.323.
Use to define the echo canceller tail
size for H.323.
Use to define the echo canceller
NLP mode for H.323.
Assigned Data
1
0 = Disable
1 = Enable
(default = 0)
1 = Fixed
2 = Self adjusting
(silence period)
3 = Self adjusting
(default = 3)
0~160
(default = 30)
0~160
(default = 60)
0~160
(default = 120)
0~270
(default = 30)
0~270
(default = 60)
0~270
(default = 120)
0~30 (-19db~ +10db
and self adjustment)
0 = Self adjustment
1 = -19db (-49dbm)
:
20 = 0db (-30dbm)
:
29 = 9db (-21dbm)
30 = 10db (-20dbm)
(default = 20)
-5000dbm ~ -7000dbm
(default = 7000)
0 = Disable
1 = Enable
(default = 1)
1 = 4ms
2 = 8ms
3 = 16ms
4 = 32ms
5 = 64ms
6 = 128ms
(default = 6)
0 = Disable
1 = Enable
(default = 1)
Issue 1.0
Level
2
3
2 - 651

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents