Program
Program Name
Number
20-13-06
Class of Service Options
(Supplementary Service) –
Automatic Off-Hook
Signaling (Automatic
Override)
21-01-09
System Options for Outgoing
Calls – Ringdown Extension
Timer (Hotline Start)
21-11-01
Extension Ringdown
(Hotline) Assignment
22-01-01
System Options for Incoming
Calls – Incoming Call Priority
30-05-02
DSS Console Lamp Table –
Busy Extension
30-05-03
DSS Console Lamp Table –
DND Extension
30-05-04
DSS Console Lamp Table –
ACD Agent Busy
30-05-05
DSS Console Lamp Table –
Out of Schedule (ACD DSS)
30-05-06
DSS Console Lamp Table –
ACD Agent Log Out (ACD
DSS)
30-05-07
DSS Console Lamp Table –
ACD Agent Log In (ACD DSS)
30-05-08
DSS Console Lamp Table –
ACD Agent Emergency (ACD
DSS)
30-05-09
DSS Console Lamp Table –
Hotel Status Code 1 (Hotel
DSS)
30-05-10
DSS Console Lamp Table –
Hotel Status Code 2 (Hotel
DSS)
2 - 598
Description/Comments
Program 20-02-03 and Program 20-
13-06 set the conditions under which
a Hotline, Reverse Voice Over or
DSS Console key indicates that an
extension is busy. With condition 1 in
the following chart, the BLF LED is
on only when both extension line
appearances are busy. In conditions
2~4, the BLF LED is on when one
line appearance is busy.
A Ringdown extension automatically
calls its programmed destination after
this time.
Define the Hotline destination
number for each extension number.
Use this option to determine if
Intercom calls or trunk calls have
answer priority when both are ringing
simultaneously.
Use to define the LED patterns for
busy extensions on the DSS
consoles.
Use to define the LED patterns for
DND extensions on the DSS
consoles.
Use to define the LED patterns for
busy ACD agents function on the
DSS consoles.
Use to define the LED patterns for
out of schedule (ACD/DSS) on the
DSS consoles.
Use to define the LED patterns for
ACD agents that are logged out on
the DSS consoles.
Use to define the LED patterns for
ACD agents that are logged in the
DSS consoles.
Use to define the LED patterns for
ACD agents in emergency on the
DSS consoles.
Use to define the LED patterns for
hotel status code 1 on the DSS
consoles.
Use to define the LED patterns for
hotel status code 2 on the DSS
consoles.
UNIVERGE SV8100
Assigned Data
0 = Off
1 = On
(default = 1 for
COS 1~15)
Refer to
Table 2-16
Extension Busy Setup on
page 2-599
0~64800
(default = 0)
(maximum 24 digits)
#
0, ,
, Pause, Hook
Flash, @ (Code to wait
for answer supervision)
(default not assigned)
0 = Intercom call priority
1 = Trunk call priority
(default = 1)
0~7
[default = 7 (On)]
0~7
[default = 3 (RW)]
0~7
[default = 7 (On)]
0~7
[default = 0 (Off)]
0~7
[default = 5 (IL)]
0~7
[default = 4 (IR)]
0~7
[default = 6 (IW)]
0~7
[default = 7 (On)]
0~7
[default = 1 (FL)]
Level
1
2
3
Hotline