UNIVERGE SV8100
Program
Program Name
Number
22-02-01
Incoming Call Trunk Setup
22-11-02
DID Translation Number
Conversion – Target Number
22-17-01
Dial-In Conversion Table Area
Setup for Time Pattern – Received
Dial
22-17-02
Dial-In Conversion Table Area
Setup for Time Pattern – Start of
Time
22-17-03
Dial-In Conversion Table Area
Setup for Time Pattern – End of
Time
22-17-04
Dial-In Conversion Table Area
Setup for Time Pattern – Dial-In
Conversion Table
Number
Operation
DID calls ring extensions like normal trunk calls.
To Activate DID Call by Time Schedule:
1.
At any display multiline terminal, press Speaker.
SV8100 Features and Specifications Manual
Description/Comments
For each Night Service Mode, enter
service type 8 when the trunk
should be a DID (DDI) Mode
Switching trunk.
For each DID Translation Table
entry (1~2000), specify the
extension the system dials after
translation.
Do not assign Received Digits
in PRG 22-11-01 when using
DID Call by Time Schedule.
Use to define the received numbers
for each Dial-In Conversion Table
(Program 22-17-02, 22-17-03 and
22-17-04).
Use to define the Starting Time for
each DID Translation table in
Program 22-17-01.
Use to define the Ending Time for
each DID Translation table in
Program 22-17-01.
Used to assign each time pattern to
a DID Translation Table Entry in
Program 22-11.
Assigned Data
Trunks 1~200
0 = Normal
1 = VRS (second
dial tone if no
VRS installed)
2 = DISA
3 = DID
4 = DIL
5 = E&M Tie line
6 = Delayed VRS
7 = ANI/DNIS
8 = DID(DDI) Mode
Switching
(default = 0)
Maximum 24 digits
(default not assigned)
Up to eight digits
(default not assigned)
0000~2359
(Time)
(default = 0000)
0000~2359
(Time)
(default = 0000)
0~2000
(default = 0)