Description
Code Restriction limits the numbers an extension user may dial. By allowing extensions to place only
certain types of calls, you can better control long distance costs. The system applies Code Restriction
according to the Code Restriction Class. The system allows for up to 15 Code Restriction Classes and
416 extensions
.
Conditions
If a Code Restriction Class has the same entries in both a permit and restriction table, the
system does not restrict the call.
Code Call Digit counting may prevent users from taking advantage of long distance
automated services like ACD and automated Technical Service.
Code Restriction is applied when accessing ARS.
If Program 21-01-10 is programmed with an entry other than 0, a call cannot have a talk path
unless the user dials at least the number of digits entered in this option when placing an out
going call. This means that an entry of 4 or higher in this program causes a problem when
dialing 000. Since it is only a 3-digit number, the call does not have a talk path, preventing
the emergency dispatcher from hearing the caller. This option should be kept at its default
setting of 0 to prevent any problem with dialing 000.
Common Permit Code Table
Use the Common Permit Code Table when you have numbers you want all Code Restriction
Classes to dial. To let all users dial 000, for example, put 000 in the Common Permit Code
Table. The Common Permit Code Table overrides the Restrict Code and Common Restrict
Code Tables. The system provides 10 tables, with 10 entries in each table. Each code is four
digits maximum, using 0~9,
Common Restrict Code Table
The Common Restrict Code Table lets you globally restrict certain numbers for all Code
Restriction Classes. To prevent all users from dialing directory assistance (1223), for
example, put 1223 in the Common Restrict Code Table. Be sure you do not allow the codes
you want to restrict in the Permit Code Table or the Common Permit Code Table. The
system provides 1 table, with 10 entries. Each code is 12 digits maximum, using 0~9,
and Recall (as a wild card).