Issue 1.0
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Program Name
Number
14-02-17
Analog Trunk Data Setup – Sync.
Ringing
20-15-01
Ring Cycle Setup – Normal
Incoming Call on Trunk
20-15-02
Ring Cycle Setup – PBX, CES
Incoming Call
20-15-04
Ring Cycle Setup – DID/DISA/
VRS
20-15-05
Ring Cycle Setup – DID/DDI
20-15-06
Ring Cycle Setup – Dial-In in the
E&M Tie Line
20-15-07
Ring Cycle Setup – Door Box
Ringing for SLT
20-15-08
Ring Cycle Setup – Virtual
Extension Ring
20-15-09
Ring Cycle Setup – Callback
20-15-10
Ring Cycle Setup – Alarm for SLT
20-15-11
Ring Cycle Setup –
Message Incoming
Call
22-03-01
Trunk Ring Tone Range – Ring
Tone Pattern
Operation
None
2 - 1066
Description/Comments
Enable or Disable per trunk.
Used to define the ring cycle for
Normal Incoming trunk calls.
Used to define the ring cycle for
PBX and CES incoming trunk calls.
Used to define the ring cycle for
DID/DISA/VRS incoming calls.
Used to define the ring cycle for
DID/DDI incoming calls.
Used to define the ring cycle for Dial
IN and E&M Tie line calls.
Used to define the ringing cycle for
Door Box Ringing for SLT terminals.
Used to define the ringing cycle for
Virtual Extensions.
Used to define the ringing cycle for
callbacks.
Used to define the ring cycle for
Alarm for SLT terminals.
VRS Waiting
Used to define the ring cycle for
incoming VRS Waiting messages.
Assign Ring Tone Ranges to trunks.
Trunks ring extensions according to
the Ring Tone Range selected in
Program 22-03-0 and the settings
made with either Service Code 720
or Program 15-02-02.
UNIVERGE SV8100
Assigned Data
1
0 = Disable
1 = Enable (default)
Ringing Cycle = 1~13
(default = 3)
Ringing Cycle = 1~13
(default = 8)
Ringing Cycle = 1~13
(default = 8)
Ringing Cycle = 1~13
(default = 8)
Ringing Cycle = 1~13
(default = 12)
Ringing Cycle = 1~13
(default = 8)
Ringing Cycle = 1~13
(default = 8)
Ringing Cycle = 1~13
(default = 11)
Ringing Cycle = 1~13
(default = 5)
Ringing Cycle = 1~13
(default = 8)
0~8
(Ring Tone Pattern
1~4)
(Melody 1~ Melody 5)
(default = 0)
Synchronous Ringing
Level
2
3

Hide quick links:

Advertisement

Table of Contents
loading