UNIVERGE SV8100
Program
Program Name
Number
81-10-07
COT Initial Data Setup –
Hookflash Time Selection 1
81-10-08
COT Initial Data Setup –
Hookflash Time Selection 2
SV8100 Features and Specifications Manual
Description/Comments
Set the Flash duration (16~4080
ms) for analog trunk CD-4COTC
circuits in Program 81-10-07.
Set the open loop disconnect
duration (16~4080 ms) for analog
trunk CD-4COTC circuits Program
81-10-08.
Assigned Data
1
0 = 20 ms
1 = 40 ms
2 = 60 ms
3 = 80 ms
4 = 100 ms
5 = 140 ms
6 = 160 ms
7 = 200 ms
8 = 400 ms
9 = 600 ms
10 = 800 ms
11 = 1.0 seconds
12 = 1.5 seconds
13 = 2.0 seconds
14 = 3.0 seconds
15 = 5.0 seconds
[default = 4 (100ms)
All Trunks]
0 = 20 ms
1 = 40 ms
2 = 60 ms
3 = 80 ms
4 = 100 ms
5 = 140 ms
6 = 160 ms
7 = 200 ms
8 = 400 ms
9 = 600 ms
10 = 800 ms
11 = 1.0 seconds
12 = 1.5 seconds
13 = 2.0 seconds
14 = 3.0 seconds
15 = 5.0 seconds
[default = 14 (3.0
seconds)]