Program
Program Name
Number
10-03-06
ETU Setup (DLC PKG Setup) –
Terminal Type (B2)
10-03-07
ETU Setup (DLC PKG Setup) –
Logical Port Number (B2)
15-07-01
Programmable Function Keys
20-07-01
Class of Service Options
(Administrator Level) – Manual
Night Service Enabled
20-07-03
Class of Service Options
(Administrator Level) – Time
Setting
20-07-05
Class of Service Options
(Administrator Level) – Set/
Cancel Automatic Trunk-to-Trunk
Transfer
20-07-11
Class of Service Options
(Administrator Level) – Forced
Trunk Disconnect (analog trunk
only)
2 - 452
Description/Comments
Use to setup and confirm the Basic
Configuration data for terminal type.
Use to setup and confirm the Basic
Configuration data for logical port
number (B2).
Assign a Department Calling key (46)
so extension users can install or
remove themselves from the
Department Calling Group. Additional
keys can also be assigned for
Department Group features
immediate calling destination (58),
delayed calling destination (59) and
DND destination (60).
Turns Off or On an extension for
manually Switching the Night Mode
(Service Code 718). This option must
be enabled for an extension to display
the Night indication.
Turns Off or On an extension user
ability to set the Time via Service
Code 728.
Turns Off or On an extension user
ability user ability to use the
Trunk-to-Trunk Forwarding service
codes.
Turns Off or On an extension user
ability to use Forced Trunk
Disconnect. This allows the extension
to disconnect an Unsupervised
Conference in progress.
UNIVERGE SV8100
Assigned Data
0 = Not set
6 = PGD(2)-U( ) ADP
(Paging)
7 = PGD(2)-U( ) ADP
(Tone Ringer)
8 = PGD(2)-U( ) ADP
(Door Box)
9 = PGD(2)-U( ) ADP
(ACI)
12 = APR (B2 Mode)
(default = 0)
0 = Not Set
6 = PGD(2)-U( ) ADP
(Ext. Speaker)
7 = PGD(2)-U( ) ADP
(Paging/Tone Ringer =
1~8)
8 = PGD(2)-U( ) ADP
(for Door Box = 1~8)
(ACI) = (1~96)
9 = PGD(2)-U( ) ADP
12 = APR (for B2 Mode)
(193~512)
(default = 0)
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~ 99 (Appearance
Function Code) (Service
Code 752 by default)
0 = Off
1 = On
(default = 0 for
COS 1~14)
(default = 1 for
COS 15)
0 = Off
1 = On
(default = 1 for
COS 1~15)
0 = Off
1 = On
(default = 0 for
COS 1~15)
0 = Off
1 = On
(default = 0 for
COS 1~14)
(default = 1 for
COS 15)
term
Cordless II Terminal
D
Level
1
2
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents