Calling Party Number Presentation for either ISDN – BRI or PRI
Program
Program Name
Number
10-03-05
ETU Setup (PRTA PKG Setup) –
CLIP Information
Announcement
15-01-04
Basic Extension Data Setup –
ISDN Caller ID
20-06-01
Class of Service for Extensions
20-08-13
Class of Service Options
(Outgoing Call Service) – ISDN
CLIP
21-12-01
ISDN Calling Party Number
Setup for Trunks
21-13-01
ISDN Calling Party Number
Setup for Extensions
SV8100 Features and Specifications Manual
Description/Comments
Based on this setting, the system
includes a Presentation Allowed (1)
or Presentation Restricted (0) in the
Setup message to allow or deny the
Calling Party Number. Program
15-01-04 must also be set to 1 if this
option is enabled.
If both Program 15-01-04 and
Program 10-03-05 are enabled (1),
the system includes Caller ID in the
Setup message as Presentation
Allowed. If these options are
disabled (0), it is Presentation
Restricted.
Assign a Class of Service (1~15) to
an extension.
Determine if the ISDN calling line
identity presentation and screening
indicators are to be allowed.
Assign Calling Party Numbers for
each trunk (maximum 16 digits per
entry). When a call is made by an
extension which does not have an
Extension Calling Number assigned
(Program 21-13), the system sends
the calling number for the ISDN trunk
defined in 21-12. If the Calling Party
Number is assigned in both Program
21-12 and Program 21-13, the
system sends the data in Program
21-13.
Assign each extension a Calling
Party Number (maximum 16 digits
per entry). The calling number is the
subscriber number of the dial-in
number. When a call is made by an
extension which does not have an
Extension Calling Number assigned
(Program 21-12), the system sends
the calling number for the ISDN trunk
defined in Program 21-13. If a Calling
Party Number is assigned in both
Program 21-12 and Program 21-13,
the system sends the data in
Program 21-13.
Assigned Data
1
0 = Disable
1 = Enable
(default = 1)
0 = Disable
1 = Enable
(default = 1)
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port
= Class 1
0 = Off
1 = On
(default = 1)
(maximum 16 digits)
#
1-0, ,
Default:
(All trunks = No setting)
#
0~9, ,
(Max. 16 digits)
(default not assigned)