Issue 1.0
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Program Name
Number
10-12-01
CD-CP00-AU Network Setup – IP
Address
10-20-01
LAN Setup for External Equipment
– TCP Port
10-20-03
LAN Setup for External Equipment
– Keep Alive Time
14-01-06
Basic Trunk Data Setup – SMDR
Printout
14-04-01
Behind PBX Setup
15-01-03
Basic Extension Data Setup –
SMDR Printout
20-07-18
Class of Service Options
(Administrator Level) – SMDR
Printout Accumulated Extension
Data
2 - 984
Description/Comments
Assign the IP Address.
Define the TCP port (0~65535)
when communicating to the SMDR
(type 5).
Use to define the keep alive time for
communicating to external
equipment.
Use this option to have the system
include(1) or exclude (0) the trunk
you are programming from the
SMDR printout. Refer to Program
35-01 and 35-02 for SMDR printout
options.
For ANI/DNIS, the following
additional setting is recommended:
Behind PBX = 0 (Stand Alone).
For each extension, enter 1 if
extension calls should appear on
SMDR report. Enter 0 if extension
calls should not appear on SMDR
report.
Used to determine if Accumulated
Extension Data is included in the
SMDR report for each COS.
UNIVERGE SV8100
Assigned Data
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~
191.254.255.254
192.0.0.1 ~
223.255.255.254
(default = 192.168.0.10)
0~65535
default:
External Device 1 (CTI
Server) = 0
External Device 2 (ACD
MIS) = 4000
External Device 5 (SMDR
Output) = 0
External Device 6 (DIM
Output) = 0
External Device 11 (O&M
Server) = 8010
1~255 (seconds)
(default = 30)
0 = No Print Out
1 = Prints Out
(default = 1)
0 = Stand Alone (Trunk)
1 = Behind PBX (PBX)
2 = Not Used
3 = CTX assume 9
(default = 0)
0 = Do not print on SMDR
report
1 = Include on SMDR
report
(default = 1)
0 = Off
1 = On
(default = 0 for
COS 1~14)
(default = 1 for
COS 15)
Station Message Detail Recording
Level
1
2
3