Juniper JUNOS OS 10.4 - FOR EX REV 1 Manual page 1546

For ex series ethernet switches
Table of Contents

Advertisement

Complete Software Guide for Junos
show diagnostics tdr
show diagnostics tdr
interface ge-0/0/19
interface ge-0/0/19
(Normal Cable)
(Normal Cable)
1442
®
OS for EX Series Ethernet Switches, Release 10.4
Table 213: show diagnostics tdr Output Fields (continued)
Field Name
Polarity swap
Skew time
Channel Pair
Pair Swap
Downshift
user@switch> show diagnostics tdr interface ge-0/0/19
Interface TDR detail:
Interface name
Test status
Link status
MDI pair
Cable status
Distance fault
Polartiy swap
Skew time
MDI pair
Cable status
Distance fault
Polartiy swap
Skew time
Field Description
Indicates the polarity status of the twisted pair:
—Polarity is normal. Each conductor in the twisted pair has
Normal
been connected the same pins at the both ends of the connection.
For example, a conductor connected to pin 1 at the near end of the
connection is connected to pin 1 at the far end.
—Polarity has been reversed. For the twisted pair, the
Reversed
conductors have switched which pins they are connected to at the
near and far ends of the connection. For example, the conductor
connected to pin 1 at the near end is connected to pin 2 at the far
end.
(Not available on EX8200 switches.) (Displayed only when the
option is used)
interface
Difference in nanoseconds between the propagation delay on this
twisted pair and the twisted pair with the shortest propagation delay.
(Not available on EX8200 switches.) (Displayed only when the
option is used.)
interface
Number of the 10/100BASE-T transmit/receive pair being reported
on.
Indicates whether or not the twisted pairs are swapped:
—The pairs are not swapped (straight-through cable).
MDI
MDIX
—The pairs are swapped (cross-over cable).
(Displayed only when the
interface
Indicates whether the connection speed is being downshifted:
No Downshift
—No downshifting of connection speed.
Downshift occurs
—Connection speed is downshifted to 10 or 100
Mbs. This occurs if the cable is a two-pair cable rather than the
four-pair cable required by Gigabit Ethernet.
(Displayed only when the
interface
: ge-0/0/19
: Passed
:
UP
: 1-2
: Normal
: 0 Meters
: Normal
: 0 ns
: 3-6
: Normal
: 0 Meters
: Normal
: 8 ns
option is used.)
option is used.)
Copyright © 2010, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junos os 10.4

Table of Contents