Table 215: show interfaces diagnostics optics Output Fields (continued)
Field Name
Module voltage
(Not available for XFP transceivers)
Laser rx power
(Not available for SFP and SFP+ transceivers)
Receiver signal average optical power
(Not available for XFP transceivers)
Laser bias current high alarm
Laser bias current low alarm
Laser bias current high warning
Laser bias current low warning
Laser output power high alarm
Laser output power low alarm
Laser output power high warning
Laser output power low warning
Module temperature high alarm
Module temperature low alarm
Module temperature high warning
Module temperature low warning
Module voltage high alarm
(Not available for XFP transceivers)
Module voltage low alarm
(Not available for XFP transceivers)
Module voltage high warning
(Not available for XFP transceivers)
Copyright © 2010, Juniper Networks, Inc.
Chapter 62: Operational Commands for Interfaces
Field Description
Displays the voltage, in Volts.
Displays the laser received optical power, in milliwatts (mW) and decibels
referred to 1.0 mW (dBm).
Displays the receiver signal average optical power, in milliwatts (mW)
and decibels referred to 1.0 mW (dBm).
Displays whether the laser bias power setting high alarm is
Displays whether the laser bias power setting low alarm is
Displays whether the laser bias power setting high warning is
Displays whether the laser bias power setting low warning is
Displays whether the laser output power high alarm is
Displays whether the laser output power low alarm is
Displays whether the laser output power high warning is
Displays whether the laser output power low warning is
Displays whether the module temperature high alarm is
Displays whether the module temperature low alarm is
Displays whether the module temperature high warning is
Displays whether the module temperature low warning is
Displays whether the module voltage high alarm is
Displays whether the module voltage low alarm is
Displays whether the module voltage high warning is
or
.
On
Off
or
.
On
Off
or
.
On
Off
or
.
On
Off
or
.
On
Off
or
.
On
Off
or
.
On
Off
or
.
On
Off
On
or
Off
.
On
or
Off
.
On
or
Off
.
On
or
Off
.
On
or
Off
.
On
or
Off
.
On
or
Off
.