3.6 I/O system

3.6.1 Available industrial networks

General
The controller can be fitted with a number of different boards and software based
industrial networks. The software based industrial networks do not require any
hardware.
Fieldbus connections
There is a slot available for installing a fieldbus board (PCIe) on the main computer,
with process connectors on the front panel.
The software based fieldbuses are connected directly to one of the Ethernet ports.
xx2100000501
A
B
Available board
The following master board is available.
Description
DeviceNet Board
Product manual - OmniCore C30
3HAC060860-001 Revision: P
Note
Two industrial network masters can be run in parallel on the OmniCore controller.
It is the responsibility of the integrator to verify the behavior when two masters
are used in one OmniCore.
Slot for fieldbus, PCI express card
Fieldbus board (master)
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
3.6.1 Available industrial networks
A
Article number
Type designation
3HAC043383-001
DSQC1006
Continues on next page
B