ABB OmniCore C30 Product Manual page 314

Hide thumbs Also See for OmniCore C30:
Table of Contents

Advertisement

5 Repair
5.2.8 Replacing the safety digital base device
Continued
Required documents
Document
Circuit diagram - OmniCore C30,
Circuit diagram - OmniCore C30
for IRB 14050, Circuit dia-
gram - OmniCore C30 for CRB
15000
Application manual - Scalable I/O
Removing the safety digital base device
Preparations
1
2
3
Removing the safety digital base device
1
Continues on next page
314
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
31.
Remove the front panel and top cover of
the controller.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
47.
Action
Disconnect:
K3.1.X5 - K2.X3
© Copyright 2019-2022 ABB. All rights reserved.
Article number
Note
3HAC059896-009,
3HAC063898-009,
3HAC072448-009
3HAC070208-001
Note/Illustration
Removing the controller covers on page
Location of wrist strap button:
xx1800000683
Note/Illustration
xx1800000498
Product manual - OmniCore C30
222.
3HAC060860-001 Revision: P