ABB OmniCore C30 Product Manual page 117

Hide thumbs Also See for OmniCore C30:
Table of Contents

Advertisement

Pin
17
18
Product manual - OmniCore C30
3HAC060860-001 Revision: P
Name
NC
NC
Note
The ESOUT1 and ESOUT2 fulfill the IEC 61131-2 Type 0,25 Output.
Note
The device connected to the ESOUT pins shall fulfill the IEC 61131-2 Type 1
Input.
If the device cannot meet the requirement, a safety PLC or relay is needed.
Customer provided device
Relay Output for
Safety Input
of Next Stage
Isola on
Relay Output for
Safety Input
of Next Stage
Isola on
xx2000001763
Note
State 0 of Emergency stop output shall be recognized as Emergency stop
triggered.
Note
The maximum length of the cable connected to the ESOUT pins shall be 10 m.
Note
The cable shall be protected from external EM disturbance, suggested to use
separate multicore cables.
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
Description
Reserved
Reserved
K2.X15
Safety PLC
or Relay
Safety PLC
or Relay
3.5.8 Descriptions for connectors
14
ESOUT1 +
13
ESOUT1
-
12
ESOUT2 +
11
ESOUT2
-
Continues on next page
Continued
117