3 Installation and commissioning
3.7.4 Installing the power supply optional device and the harness 24 V extension
Continued
3
4
Refitting the axis computer to the frame
1
2
3
Continues on next page
164
Action
Secure the optional power supply with
the screws.
Connect:
A1.X7 - T5.X1
Note
The connector on the AC_in cable
(3HAC061099-001) is fastened to the
cable clip in the illustration when the
power supply optional is not selected.
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
31.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
47.
Reconnect and secure the screw:
K6.X4, K6.X5 - SMB.
© Copyright 2019-2022 ABB. All rights reserved.
Note/Illustration
Screws: Torx pan head screw M4x8 (4 pcs)
xx1800001188
A
Cable clip
Note/Illustration
Location of wrist strap button:
xx1800000683
Product manual - OmniCore C30
3HAC060860-001 Revision: P
A

Hide quick links: