5 Repair
5.3.5 Replacing the process connectors
Continued
Removing the process connectors
1
2
3
4
5
Refitting the process connectors
Refitting the process connectors
1
Continues on next page
462
Action
Push the cables out from the clips in the
bottom of the controller carefully.
Note
Make records about the sequence that
cables are removed. The cables need to
be installed in the same position.
Remove the attachment screws on the
front panel.
Push the process connectors into the
cabinet.
Push the cables on process connectors
out from the clips on the bottom of the
cabinet.
Take the process connectors out from
the upper side.
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
31.