Refitting the robot signal exchange proxy
1
2
3
4
Product manual - OmniCore C30
3HAC060860-001 Revision: P
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
31.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
47.
Fit the robot signal exchange proxy and
secure the screws.
Note
Avoid colliding with the frame of the
controller.
Insert the cable ties into the locking
holes.
© Copyright 2019-2022 ABB. All rights reserved.
5.2.3.3 Replacing the main computer fan
Note/Illustration
Location of wrist strap button:
xx2000000532
Screws: Torx pan head screw M4x8 (4 pcs)
xx1800000489
xx1800000971
Continues on next page
5 Repair
Continued
277