4.2 Inspection activities

4.2.1 Inspection of controller

Inspecting the OmniCore C30 controller
1
2
3
4
Product manual - OmniCore C30
3HAC060860-001 Revision: P
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
31.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
47.
Inspect connectors and cabling to make
sure they are securely fastened and
cabling not damaged.
Inspect the fans and ventilation holes to
make sure they are clean.