ABB OmniCore C30 Product Manual page 447

Hide thumbs Also See for OmniCore C30:
Table of Contents

Advertisement

2
3
4
Product manual - OmniCore C30
3HAC060860-001 Revision: P
5.3.4 Replacing the HMI signal (FlexPendant) connector
Action
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
47.
Insert the HMI signal connector into the
front panel from inside the cabinet.
Secure it with the screws.
Insert the cables on HMI signal connector
into the clips on the bottom of the cabin-
et.
Tip
Use the same position as from removing
HMI connector.
© Copyright 2019-2022 ABB. All rights reserved.
Note/Illustration
Location of wrist strap button:
xx1800000683
Screws: Torx, countersunk screw M4x10 (4
pcs)
xx1800000736
xx1900001007
Continues on next page
5 Repair
Continued
447

Hide quick links: