5 Repair
5.2.3.2.3 Replacing the new small fan
Continued
2
3
4
5
Concluding procedure
1
Continues on next page
262
Action
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
47.
Reconnect:
•
G2.X1-K2.X17
Refit the fan bracket into the cabinet.
Secure it with the screws.
Action
Refit the covers.
© Copyright 2019-2022 ABB. All rights reserved.
Note/Illustration
Location of wrist strap button:
xx1800000683
xx2000002115
Screws: Torx, countersunk screw M4x10 (2
pcs)
xx2000002113
Note/Illustration
Refitting the controller covers on page
Product manual - OmniCore C30
3HAC060860-001 Revision: P
227.