5
6
Refitting the axis computer to the frame
1
2
3
Product manual - OmniCore C30
3HAC060860-001 Revision: P
Action
Secure the screws.
Reconnect:
A1.X7 - T5.X1
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
31.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
47.
Reconnect and secure the screw:
K6.X4, K6.X5 - SMB.
© Copyright 2019-2022 ABB. All rights reserved.
5.2.11 Replacing the power supply
Note/Illustration
Screws: Torx pan head screw M4x8 (4 pcs)
xx1800000550
Note/Illustration
Location of wrist strap button:
xx1800000683
Continues on next page
5 Repair
Continued
371