Product manual - OmniCore C30
3HAC060860-001 Revision: P
5.3.2.2 Replacing the motor connector for CRB 15000 controller
Action
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
47.
Insert the motor connector into the front
panel from inner side of the cabinet and
fasten it with the screws.
Reconnect:
•
X1 - X105
•
X1 - X106
•
X1 - A1.X4
•
X1 - A2.X9
•
Two ground cables which con-
nects on the left side of the cabin-
et frame.
Insert the cables on motor connector into
the clips in the bottom of the cabinet.
Tip
Use the same position as from removing
the motor connector.
© Copyright 2019-2022 ABB. All rights reserved.
Note/Illustration
Location of wrist strap button:
xx1800000683
Screws: Torx, countersunk screw M4x10 (4
pcs)
xx1800000730
Continues on next page
5 Repair