Removing the small fan
1
2
3
Disconnecting the connectors to the main computer assembly
1
Product manual - OmniCore C30
3HAC060860-001 Revision: P
Action
Remove the screws holding the fan.
Push and slide the fan bracket and lift it
out.
Disconnect:
G2.X1-K2.X17
Action
Disconnect all the connectors on the as-
sembly group of the robot signal ex-
change proxy, Ethernet switch (option),
connected services gateway, scalable
I/O (option), and main computer.
© Copyright 2019-2022 ABB. All rights reserved.
5.2.9 Replacing the main computer
Note/Illustration
xx1800000479
xx1800000480
Note/Illustration
Continues on next page
5 Repair
Continued