5 Repair
5.3.3 Replacing the incoming mains connector
Continued
2
3
4
5
Concluding procedure
1
2
438
Action
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
47.
Reconnect:
•
K6.X4, K6.X5 - SMB.
Fit the axis computer bracket and secure
the screws.
Reconnect:
•
K6.X11 - A1.X3
•
K6.X2 - A2.X9
•
K6.X1 - K2.X3
Action
Refit the covers.
Perform the function tests to verify that
the safety features work properly, see
Function tests on page
212.
© Copyright 2019-2022 ABB. All rights reserved.
Note/Illustration
Location of wrist strap button:
xx1800000683
Screws: Torx pan head screw M4x8 (4 pcs)
xx1900001201
Note/Illustration
Refitting the controller covers on page
Product manual - OmniCore C30
3HAC060860-001 Revision: P
227.