5 Repair
5.2.3.1.2 Replacing the standard fan to a standard size silent fan unit
Continued
5
6
7
Concluding procedure
1
2
246
Action
Refit the standard fan with the bracket.
Push and slide the bracket into position.
Secure the screws.
Reconnect:
G1.X2-K2.X17
Action
Refit the covers.
Perform the function tests to verify that
the safety features work properly, see
Function tests on page
212.
© Copyright 2019-2022 ABB. All rights reserved.
Note/Illustration
xx2000002206
xx2000002207
Screws: Torx, countersunk screw M4x10 (4
pcs)
xx2000002215
Note/Illustration
Refitting the controller covers on page
Product manual - OmniCore C30
3HAC060860-001 Revision: P
227.