ABB OmniCore C30 Product Manual page 333

Hide thumbs Also See for OmniCore C30:
Table of Contents

Advertisement

2
3
4
Refitting the main computer assembly with process plate to the cabinet
1
Product manual - OmniCore C30
3HAC060860-001 Revision: P
Action
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
47.
Fit the robot signal exchange proxy and
secure the screws.
Note
Avoid colliding with the frame of the
controller.
Insert the cable ties into the locking
holes.
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
31.
© Copyright 2019-2022 ABB. All rights reserved.
5.2.9 Replacing the main computer
Note/Illustration
Location of wrist strap button:
xx2000000532
Screws: Torx pan head screw M4x8 (4 pcs)
xx1800000489
xx1800000971
Note/Illustration
Continues on next page
5 Repair
Continued
333

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents