2 Controller description
2.2 Technical data for OmniCore C30 controller
Continued
Power supply
Mains
Voltage for OmniCore C30
Voltage tolerance
Frequency
Frequency tolerance
i
Load current
There is no integrated fuse inside the OmniCore C30 controller. Add an external
fuse (time-delay) or circuit breaker (class K) according to full load current, as
marked on the controller nameplate. The following table shows the recommended
rating for an external fuse or circuit breaker.
Add an external circuit breaker (class K) according to full load current, as marked
on the controller nameplate. The following table shows the recommended rating
for an external fuse or circuit breaker.
Robot
IRB 1100
IRB 1200
IRB 1300
IRB 910INV
IRB 920
IRB 360
IRB 14050
CRB 1100
CRB 15000
Residual current
An external earth fault protection (residual current device, RCD) is required based
on the following data:
Robot
IRB 1100
IRB 1200
Continues on next page
42
For IRB 14050 controller and CRB 15000 controller.
Note
The 2 phases (180-degree phase shift, with grounded neutral), also called
Single-phase three-wire system in North America, can be supported by this
controller.
© Copyright 2019-2022 ABB. All rights reserved.
Value
220/230 VAC, 1 phase
100-230 VAC, 1 phase
+10%, -15%
+10%, -10%
50/60 Hz
±3%
Current (A)
220/230 VAC, 1 phase
220/230 VAC, 1 phase
220/230 VAC, 1 phase
220/230 VAC, 1 phase
220/230 VAC, 1 phase
220/230 VAC, 1 phase
100-230 VAC, 1 phase
220/230 VAC, 1 phase
100-230 VAC, 1 phase
Residual Current in controller (mA)
< 30 mA
< 30 mA
i
i
Description
10 A
10 A
10 A
10 A
10 A
10 A
6 A
10 A
16 A in 100 VAC
6 A in 230 VAC
Product manual - OmniCore C30
3HAC060860-001 Revision: P