3 Installation and commissioning
3.5.7 Ethernet networks on OmniCore
Continued
As an exception to the reserved ranges mentioned in section
on page
reserved range 192.168.126.0 - 255, but not within 192.168.125.0 - 255 or
192.168.127.0 - 255.
For security reasons, only outbound access on port 53 DNS and 443 HTTPS are
allowed. The inbound access is blocked by an internal firewall and cannot be
unblocked.
Public Network
The Public Network interface is typically connected to the factory network with a
public IP address provided by the network administrator. The Public Network
segment can be used for:
Most protocols are disabled by default in the controller firewall. See
on page 111
The Public Network can be configured with a fixed IP address, or as a DHCP client,
either in RobotStudio or from the FlexPendant:
Continues on next page
108
107, the Ability Network is allowed to configure IP addresses within the
Note
For more information about connecting the Ability port to the internet, see
Application manual - Controller software OmniCore.
Connecting a PC running RobotStudio. For more information see Operating
manual - RobotStudio.
Mounting FTP or NFS disks from the controller.
Running Industrial Ethernet protocols.
for information about how to enable these protocols.
Defining network settings in RobotStudio:
1 In the Configuration browser, right-click the controller and select
Properties\Network Settings and then Public Network.
© Copyright 2019-2022 ABB. All rights reserved.
Reserved IP addresses
Firewall settings
Product manual - OmniCore C30
3HAC060860-001 Revision: P