ABB OmniCore C30 Product Manual page 124

Hide thumbs Also See for OmniCore C30:
Table of Contents

Advertisement

3 Installation and commissioning
3.5.8 Descriptions for connectors
Continued
The following table shows the connections to the DeviceNet connector:
I/O pin
1
2
3
4
5
This connector is internally connected with the optional DeviceNet board
(DSQC1006). The X17 is the predefined connection to the DeviceNet board in main
computer for the customer.
For connection details, see Circuit diagram - OmniCore C30, Circuit
diagram - OmniCore C30 for IRB 14050, Circuit diagram - OmniCore C30 for CRB
15000, 3HAC059896-009, 3HAC063898-009, 3HAC072448-009.
X45 - IP20 power outlet connector (option)
xx1700001064
A
Continues on next page
124
Signal name
V-
CANL
Shield
CANH
V+
Tip
The DeviceNet network needs to be powered by a separate 24 V power supply,
or the DeviceNet function will not work.
See Application manual - DeviceNet Master/Slave, 3HAC066562-001, section
"Hardware overview" for more information on how to connect 24 V to the
DeviceNet network.
A
IP20 Power outlet connector
© Copyright 2019-2022 ABB. All rights reserved.
Wire color
Function
black
DeviceNet network negative power ( 0 V)
blue
DeviceNet communication network terminal
(low)
bare
Network cable shield
white
DeviceNet communication network terminal
(high)
red
DeviceNet network positive power ( 24 V DC)
Product manual - OmniCore C30
3HAC060860-001 Revision: P

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents