5 Repair
5.3.4 Replacing the HMI signal (FlexPendant) connector
Continued
2
3
Removing the main computer assembly with process plate
1
47 Not available for CRB 15000 controller.
48 Only available for CRB 15000 controller.
Continues on next page
442
Action
Remove the screws on the bracket.
Loosen the screw and disconnect:
K6.X4, K6.X5 - SMB.
Action
Disconnect all the connectors on the as-
sembly group of the robot signal ex-
change proxy, Ethernet switch (option),
connected services gateway, scalable
I/O (option), and main computer.
For the robot signal exchange proxy:
K2.X8 - A2.X6
(option): K2.X2 - K4.X8, A2.X1
K2.X12 - A2.K3.X6, A2.K3.X7
K2.X10 - A1.X13
K2.X21 - TempSensor
K2.X4 - A1.X9
K2.X3 - K6.X1, A2.K3.X1, K5.1.X4,
K7.X1
47
K2.X1 - T2.X2
48
K2.X1 - X107
K2.X17 - G2.X1, G1.X2
K2.X6, K2.X11 - A1.X2
K2.X7, K2.X22 - Harn. LV robot
power (X1)
K2.X9 & X13 - FlexPendant (X4)
© Copyright 2019-2022 ABB. All rights reserved.