ABB OmniCore C30 Product Manual page 551

Hide thumbs Also See for OmniCore C30:
Table of Contents

Advertisement

LEDs
The illustration below shows the LEDs on the power supply.
xx1800000582
A
Description
DC OK LED
Required test equipment
Equipment needed for troubleshooting.
Equipment
Multimeter
Insulating gloves
Circuit diagram - OmniCore C30, Circuit dia-
gram - OmniCore C30 for IRB 14050, Circuit
diagram - OmniCore C30 for CRB 15000
Preparations
1
2
3
Product manual - OmniCore C30
3HAC060860-001 Revision: P
DC OK LED
Significance
Green: All DC outputs are above the specified minimum levels.
Off: One or more DC outputs are below the specified minimum level.
Action
Check the FlexPendant for errors and warnings.
Power the controller off. Wait one minute, power the controller on.
Wait 30-60 seconds after power-on.
Make sure that the control system power is in run-time mode.
© Copyright 2019-2022 ABB. All rights reserved.
6 Troubleshooting
6.3.10 Troubleshooting the power supply
Note
3HAC059896-009, 3HAC063898-009,
3HAC072448-009
Continues on next page
Continued
A
551

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents