ABB OmniCore C30 Product Manual page 428

Hide thumbs Also See for OmniCore C30:
Table of Contents

Advertisement

5 Repair
5.3.2.2 Replacing the motor connector for CRB 15000 controller
Continued
Removing the motor connector
1
2
3
4
5
Refitting the motor connector for CRB 15000 controller
Refitting the motor connector
1
Continues on next page
428
Action
Disconnect the following connectors for
the motor connector:
X1 - X105
X1 - X106
X1 - A1.X4
X1 - A2.X9
Two ground cables which con-
nects on the left side of the cabin-
et frame.
Remove the attachment screws on the
front panel.
Push the motor connector into the cabin-
et.
Take the motor connector cable out from
the velcro in the cabinet.
Note
Make records about the sequence that
cables are removed. The cables need to
be installed in the same position.
Take the motor connector out from the
upper side.
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
31.
© Copyright 2019-2022 ABB. All rights reserved.
Note/Illustration
xx1800000729
Note/Illustration
Product manual - OmniCore C30
3HAC060860-001 Revision: P

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents