3 Installation and commissioning
3.5.8 Descriptions for connectors
Continued
A protective stop device needs to be connected to the protective stop input. See
example below.
Customer provided
protec ve stop device
xx2100002262
The protective stop input can be powered from an external power supply:
Customer provided power
xx2100002264
Continues on next page
114
K2.X14
16
14
13
15
10
12
11
9
Customer provided
protec ve stop device
Customer_24V_CH1
Customer_0V_CH1
Customer_24V_CH2
Customer_0V_CH2
© Copyright 2019-2022 ABB. All rights reserved.
24V_CH1
AS1+ / GS1+
AS1- / GS1-
0V_CH1_CH2
24V_CH2
AS2+ / GS2+
AS2- / GS2-
0V_CH1_CH2
K2.X14
16
24V_CH1
AS1+ / GS1+
14
AS1- / GS1-
13
15
0V_CH1_CH2
10
24V_CH2
AS2+ / GS2+
12
AS2- / GS2-
11
9
0V_CH1_CH2