5 Repair
5.3.2.1 Replacing the motor connector
Continued
Refitting the power supply optional
1
2
3
4
5
6
Continues on next page
422
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
31.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
47.
Fit the power supply.
Reconnect:
T5.X2 - X45.
Secure the screws.
Reconnect:
A1.X7 - T5.X1
© Copyright 2019-2022 ABB. All rights reserved.
Note/Illustration
Location of wrist strap button:
xx1800000683
Screws: Torx pan head screw M4x8 (4 pcs)
xx1800000550