Concluding procedure
1
2
Product manual - OmniCore C30
3HAC060860-001 Revision: P
5.3.2.2 Replacing the motor connector for CRB 15000 controller
Action
For the main computer:
K2.X8 - A2.X6
K2.X2 - K4.X8, A2.X1
K2.X12 - A2.K3.X6, A2.K3.X7
53
A2.X9 - K6.X2
54
A2.X9 - X1
A2.X5 - K7.X2
(Option) A2.K1 - X17
Note
This cable is available when the
fieldbus master and DeviceNet
harness are installed.
(Option) A2.X4 - K4.X6
Note
When Ethernet extension switch
is selected, connect and discon-
nect the connector A2.X4) to/from
K4.X6.
(Option) Harness adapter -
A2.X4/K4.X7
Note
When Ethernet extension switch
is selected, connect and discon-
nect the adapter cable (Adapter -
A2.X4/K4.X7) to/from K4.X7.
When Ethernet extension unit slot
cover is selected, connect and
disconnect the adapter cable (Ad-
apter - A2.X4/K4.X7) to/from
A2.X4.
For the digital base (option):
K5.1.X4 - K2.X3
K5.1.X5 - Harness adapter
For connected services gateway wired, there is no power cable.
Action
Refit the covers.
Perform the function tests to verify that
the safety features work properly, see
Function tests on page
212.
© Copyright 2019-2022 ABB. All rights reserved.
Note/Illustration
Note/Illustration
Refitting the controller covers on page
5 Repair
Continued
227.