Removing the small fan
1
2
3
Refitting the Ethernet extension switch (option)
1
Product manual - OmniCore C30
3HAC060860-001 Revision: P
Action
Remove the screws holding the fan.
Push and slide the fan bracket and lift it
out.
Disconnect:
G2.X1-K2.X17
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
31.
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
3.7.3 Installing the Ethernet extension switch
Note/Illustration
xx1800000479
xx1800000480
Note/Illustration
Continues on next page
Continued
147