5 Repair
5.3.2.1 Replacing the motor connector
Continued
2
3
4
5
Refitting the motor connector
Refitting the motor connector
1
43 This procedure is not available for the CRB 15000 controllers.
Continues on next page
420
Action
Remove the attachment screws on the
front panel.
Push the motor connector into the cabin-
et.
Take the motor connector cable out from
the velcro in the cabinet.
Note
Make records about the sequence that
cables are removed. The cables need to
be installed in the same position.
Take the motor connector out from the
upper side.
43
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
31.