5 Repair
5.2.9 Replacing the main computer
Continued
2
3
4
5
Refitting the small fan
1
Continues on next page
338
Action
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
47.
Reconnect and secure the screw:
•
K6.X4, K6.X5 - SMB.
Fit the axis computer bracket and secure
the screws.
Reconnect:
•
K6.X11 - A1.X3
•
K6.X2 - A2.X9
•
K6.X1 - K2.X3
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
31.
© Copyright 2019-2022 ABB. All rights reserved.
Note/Illustration
Location of wrist strap button:
xx1800000683
Screws: Torx pan head screw M4x8 (4 pcs)
xx1800000476
Note/Illustration
Product manual - OmniCore C30
3HAC060860-001 Revision: P