5 Repair
5.2.5 Replacing the Ethernet switch
Continued
4
5
Concluding procedure
1
2
298
Action
Refit the fan bracket into the cabinet.
Secure it with the screws.
Action
Refit the covers.
Perform the function tests to verify that
the safety features work properly, see
Function tests on page
212.
© Copyright 2019-2022 ABB. All rights reserved.
Note/Illustration
xx1800000483
Screws: Torx, countersunk screw M4x10 (2
pcs)
xx1800000484
Note/Illustration
Refitting the controller covers on page
Product manual - OmniCore C30
3HAC060860-001 Revision: P
227.